Power Supply  
Display  
Input  
Comparator Output  
Output  
Quantity:
 

Description  more details

  • Modular Panel Meter Systems - AC Voltage True RMS
  • External Control
  • Set Point Comparator with Relay or Photocouple output
  • Output modules -setpoint- analog - RS232 & RS485
  • Universal power supply 90-264VAC or 6-60VDC Dual display option for setpoint comparator

All the code 4 options listed below are user selectable on this unit.
The multi display (set point display) is only needed if the comparator output option is selected

AC Voltage True RMS
Output Modules
Analog Output (isolated from input (LO))
Any display range to output analog signal can be set
Output Method PWM
Scaling Digital Scaling
Output Resistive load Accuracy
23 degs C +/- 5 degs
Ripple
0 to 1 V > 10 KOhms +/- 0.5% full scale 50 mV p-p
0 to 10 V > 10 KOhms
1 to 5 V > 10 KOhms
4 - 20 mA less than 550 Ohms 25 mV p-p

 

External Control

Start/Hold : Shorted between COM terminal and start/hold terminal or same level --> hold Open COM terminal and start/hold terminal or 5 V --> start
D. ZERO : Shorted between COM terminal and D.ZERO terminal --> ON
P.HOLD : Shorted between COM terminal and P. HOLD terminal --> ON
R.RE (relay reset) : Shorted between COM terminal and R.RE terminal --> ON
P.SEL1 to 3 : as below

  pattern 1 pattern 2 pattern 3 pattern 4 pattern 5 pattern 6 pattern 7 pattern 8
P.SEL1
OFF ON OFF ON OFF ON OFF ON
P.SEL2 OFF OFF ON ON OFF OFF ON ON
P.SEL3 OFF OFF OFF OFF ON ON ON ON
ON : Shorted between COM terminal and P.SEL terminal or same level
OFF : Open between COM terminal and P.SEL terminal or 5 V
Comparator Hi - Lo Set Point with relay output module
Control Method Computation by microcomputer
Measuring range
comparison
high/Low limit setting including polarity, -9999 to + 9999
Setting condition By sampling period
No setting condition for set value
Comparison Conditions  
Indication > High setpoint HI
High set point >/= indication>/= Lo Set point GO
Indication< Lo set point LO
Comparison Relay
contact capacity
AC125 V 0.3 A resistive load
DC30 V 1A resisitive load
Photo-coupler output DC30 V 50 mA
Hysteresis Settable from 1 to 9999 digits for each comparison set value

      

RS232 output module for A6000 DPM
Communication method Full duplex
Synchronous method Start and Stop
Transmission speed /4800/9600/19200/38400 bps
Start Bit 1 Bit
Data length 7 Bit /8 Bit
Error detection Even /odd parity
Stop Bit 1 / 2 Bits
Character Code ASC II
Transmission control none

 

RS485 output module for A6000 DPM
Communication method Full Duplex
Synchronous method Start and Stop
Transmission speed /4800/9600/19200/38400 bps
Start Bit 1 Bit
Data length 7/8 Bit
Parity Even/odd parity
Error detection BCC (Block Check Character) Check sum
Stop Bit 1/2Bits
Character Code ASC II
Transmission control none
Signal Name Signal Direction
Non-reversible output + Input/output
Reversible output - Input/output
Number of connectable meters Up to 31 units
cable length up to 500 m in total

 

 

Specifications
Main Display Red LED 20 mm high
Sub Display Green LED 6 mm high
Conversion Rate 1000/sec
Maximum Display 9999
Over-range indication displays "OVER" or "-OVER"
Zero Display Leading "zero" suppression
Decimal point Set to any position
Operating Temperature 0~ 50° C, 35 - 85% RH
Storage Temperature -10 ~+70° C, < 60% RH
Power Supply AC 100 - 240 Volts (AC Main Unit) +/-10%
DC 12 - 48 V ) DC main unit ) +/-10%
Power Consumption ~ 8VA (max load)
Dimensions mm 96 x 48 x 97.5
Weight 450 g
Dielectric strength (AC)Power supply/ input terminal/ output terminal - AC 1500V 1minute
(DC)Input terminal /output terminal - DC 500 V 1 minute
(Common) case/each terminal AC1500 V/min