click on thumbnail to zoom
Item #: HD2302
Our Price: $455.00
Include Meter  
Choose Probe  
Quantity:
 

Description 

The HD2302.0 is a portable instrument with a large LCD display. It measures illuminance, luminance, PAR and irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve). The probes are equipped with the SICRAM automatic detection module: in addition to detection, the unit of measurement selection is also automatic. The factory calibration data are already memorized inside the instruments. The Max, Min and Avg function calculate the maximum, minimum or average values. Other functions include: the relative measurement REL, the HOLD function, and automatic turn off and override. The instruments have IP67 protection degree.

  • VIS-NIR UVA, UVB, UVC, PAR, Solar Radiation
  • Selection of intelligent probes
  • Max Min and Average functions
  • Large range of sensors
  • Large Backlit LCD Display
  • Batteries or external power supply
  • Data sheet in PDF with spectral data
HD2302.0 Device for measuring illuminance, luminance, PAR, irradiance. Storage of maximum, minimum, average value. Functions:
REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Supplied with carrying case, instruction
manual, 3 batteries. LP471 series probes with SICRAM module are suitable. The probes have to be ordered separately.
  L471 Probes to work with the above meter
LP471 PHOT Photometric probe for measuring ILLUMINANCE, spectral response in agreement with standard photopic vision, Class B according to CIE n°69, diffuser for cosine correction. Measurement range: 0.10 lux…200·103 lux.
LP471 LUM 2 Photometric probe for measuring LUMINANCE spectral response in agreement with standard photopic vision, vision angle 2°. Measurement range: 1.0 cd/m2…2000·103 cd/m2
LP471 PAR Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range PAR (Photosynthetically Active Radiation 400nm…700nm), measurement in μmol·m-2s-1, diffuser for cosine correction.
Measurement range: 0.10μmol·m-2s-1…10·103μmol·m-2s-1.
LP471 PAR02 Quantum-radiometric probe for measuring the PHOTONS FLOW in the chlorophyll field PAR (photosynthetically Active Radiation 400…700 nm), μmol m-2s-1 measure, opaline quartz diffuser for cosine correction.
The probe uses a special filter that optimizes the spectral response.
Measuring range 0.1 μmol m-2s-1…10·103 μmol m-2s-1. Cable length 2 m.
LP471 RAD Radiometric probe for measuring IRRADIANCE module; in the 400nm…1050nm spectral range, diffuser for cosine correction.
Measurement range: 1.0·10-3W/m2…2000W/m2.
LP471 UVA Radiometric probe for measuring IRRADIANCE equipped with in the 315nm…400nm, peak 360nm, UVA spectral range, quartz diffuser for cosine correction. Measurement range: 1.0·10-3W/m2…2000 W/m2.
LP471 UVB Radiometric probe for measuring IRRADIANCE in the 280nm…315nm, peak 305nm ... 310nm, UVB spectral range, quartz
diffuser for cosine correction. Measurement range: 1.0·10-3W/m2…2000 W/m2.
LP471 UVC Radiometric probe for measuring IRRADIANCE in the 220nm…280nm, peak 260nm, UVC spectral range, quartz diffuser
for cosine correction. Measurement range: 1.0·10-3W/m2…2000 W/m2.
LP471 BLUE Radiometric probe for measuring IRRADIANCE (W/m2) in spectral band of blue light.
Spectral range: 380 nm…550 nm, quartz diffuser for cosine correction.
Measurement range: 1.0·10‑3Weff /m2 … 2000 Weff /m2.
LP 471 P-A: Combined probe for measuring ILLUMINANCE (lux), with standard photopic response, and IRRADIANCE (μW/cm2) in the UVA spectral range (315...400 nm, with peak at 360 nm). Both the sensors are equipped with diffuser for the correction according to the cosine law.
Illuminance measuring range: 0.10 lux … 200·103 lux
Irradiance measuring range: 1.0 mW/m2 … 2000 W/m2.
This probe provides the ratio between UVA irradiance and illuminance in μW/lumen (quantity of interest in museums).
The probe is equipped with SICRAM module and cable 2m long.
LP471 A-UVeff Combined probe for measuring the TOTAL EFFECTIVE IRRADIANCE (W/ m2) weighted according to the UV action curve. The probe is made of two sensors for the correct measure of the Total Effective Irradiance in the range 250...400nm.
Both these sensors are equipped with a diffuser for the correction according to the cosine law.
This probe supplies the Total effective irradiance (Eeff), the UV-CB effective irradiance and the UVA Irradiance.
Total effective irradiance measuring range: 0.010 W/m2 … 20 W/m2.
B_C effective irradiance measuring range: 0.010 W/m2 … 20 W/m2.
UVA irradiance measuring range: 0.1 W/m2 … 2000 W/m2.
The probe is equipped with the SICRAM module and a cable 2m long.
LP 471 SILICONPYRA Pyranometer with silicon photodiode to measure the GLOBAL SOLAR IRRADIANCE, diffuser for cosine correction.
Spectral range: 400…1100 nm. Measuring range: 1 mW/m2…2000 W/m2. Fixed cable 5m long,
LP 471 PYRA 03.5 Probe consisting of a second class (ISO9060) pyranometer LP PYRA 03 and a 5m long cable complete with SICRAM intelligent probe module which contains the probe ID and calibration data.

Electronics Specifications

Model HD2302.0
Measuring Units lux - fcd - μmol/m2·s - cd/m2 - W/m2 - μW/cm2μW/lumen
Connections  
  Input module for the probes 8-pole male DIN45326 connector
  Mains adapter 2-pole connector (positive at centre)
Dimensions 140x88x38mm
Weight 160 g
Case Materials ABS rubber
Batteries / life 3 1.5V type AA / 200h with 1800mAh alkaline
Operating temperature /storage temperture -5…50°C / -25…65°C
Relative Humidity 0-90% non condensing
Protection IP67

Reviews

Be the first to submit a review on this product!
Review and Rate this Item

Share







Pin It

Email A Friend

Send your friend a link to this product.