click on thumbnail to zoom
Item #: IAQ-WAC
Our Price: $215.00
Display  
Relay Output  
Temp. & Humidity  
Quantity:
 

Description  more details

Why monitor Carbon Dioxide? High levels of CO2 can cause drowsiness and create an inefficient work environment for building occupants. To combat this problem, building managers may choose to run the ventilation system continuously, but this is an inefficient, costly practice. With IAQPoint2 in place, the ventilation system can do its job appropriately and efficiently, to the benefit of your bottom line.

 User-Friendly Touchscreen Operation
• Menu driven, customizable, easy-to-navigate display
• Large 1.9 x 2.6 in (4.9 x 6.5 cm) VGA screen with
easy-to-read LCD digits and graphical display
Flexible, Money-Saving Design
• Simple wall- or duct-mount
• Multi-analog or digital (BACnet, Modbus) options
• DC and AC power; fits standard junction box
• 15 year sensor life with automatic self-calibration
• Adjustable set-points and optional relay for local
fan activation
3-in-1 Monitoring
• Choose reliable CO2 or VOC sensing technologies (VOC Version is listed separately)
• Optimize room comfort through temperature control
"Green" Attributes
• Obtain LEED credits
• Meet ASHRAE 62.1 standard
• Low power consumption and ‘sleep mode’ feature
• Optimize HVAC use and extend life of components

OTHER FEATURES:
Override feature – Reset demand control ventilation settings based on room occupancy (e.g. during off-peak hours) Temp/rH sensor – Adjust room temperature at the touch of a button; eliminate extra IAQ devices

Calibration Port – Connect calibration tube for fast, accurate bump test; calibrate IAQPoint2 without opening the casing

CO2 sensor – Monitor gas concentration readings to drive demand-controlled ventilation; achieve savings and comfort by avoiding over or under-ventilation

USB Port – Update display graphics with logo and contact information; allow future uploads of product enhancements

Model IAQPoint2 with CO2 Sensor IAQPoint2 with VOC Sensor
Gasses CO2 Volatile Organic Compounds (VOC)
Detection Method Non-dispersive infrared (NDIR) with ABC automatic background
calibration algorithm
Metal oxide semiconductor (MOS)
Ranges 0-2,000 ppm
0-10,000 ppm
0-100%
(400-2,000 ppm CO2 Equivalent)
Accuracy
± 30 ppm ± 5 % of reading
Response Time
T90 < 60 seconds
Calibration
No Calibration Required
Temperature Sensor  
Detection Method Band Gap
Range --40° to 257°F (40° to 125°C)
Accuracy ±1°C at 25°C and 50% rH
Humidity Sensor  
Detection Method Capacitive Type
Range 0-100% rH
Accuracy ±2% rH between 20% and 80% rH
System Operation  
Temperature 32° to 122°F (0 to 50°C)
Humidity 0 to 95% RH, Non-condensing
Power In 20 to 30 VAC; 18 to 28 VDC;
Consumption 200 mA @ 24 VDC
Dimensions 3.0 (w) x 4.6 (h) x 1.5 (d) in (11.8 x 7.7 x 3.7 cm)
Weight .44 lbs (.20 kg)
Enclosure ABS Alloy
Display TFT, Multicolor graphical touch screen display; 1.9 (w) x 2.6 (h) in (4.9 x 6.5 cm) (Optional with Analog units)
Languages English, French for first release
Outputs  
Analog 4-20 mA, 0-10VDC selectable
Digital Modbus RTU, BACnet MS/TP, LON
Relay 3 Amps, 250 VAC resistive, and 30 VDC SPDT; Field configurable set point & hysteresis
Override Selectable on Display Units
Mounting Options  
Wall Mount P22
Duct Mount P54
Certifications  
US ANSI/UL 61010-1
Canada CAN/CSA C22.2 No. 61010-1
Europe CE EN 13779-2007
Warranty 5 years

Reviews

Be the first to submit a review on this product!
Review and Rate this Item

Other Items In This Category

Share







Pin It

Email A Friend

Send your friend a link to this product.