AP 168 True RMS AC voltage / current with outputs
|
|
|
|
Top > Electronics Digital Panel Meters > Digital Panel Meters > AC Voltage > AP 168 True RMS AC voltage / current with outputs |
|
|
| |
|
 |
AP 168 True RMS AC voltage / current with outputs SKU: AP168
Prices from: $310.00
|
|
AP 168 True RMS AC voltage / current with outputs Description
|
Features
- True R.M.S.
- Ranges 0 ~ 1A, 0 ~ 5A (current transformer) can adjust
full scale 100 -9999
- Ranges from 99.99uA to 99.99mA
- Ranges from 99.99mV to 99.99V and 700V
- Leading zero suppression
- BCD or analog output option
- Red LED 4 digit display
| Input
Configuration |
Single Ended impedance
approx 1MOhm |
| Rectifier
Circuit |
True RMS value is obtained
in AC/DC converter in the analog operation method using transistor Vbe
nlc |
| Conversion rate |
2.5/sec |
| Response Speed |
Approx 1 sec ( 10 ~ 90%
) |
| Zero Stability |
Automatic zero
adjustment |
| Display |
LED 14.2mm 4
digit |
| Decimal point |
Set to any
position |
| Zero Display |
Leading zero
suppression |
| Overrange
indication |
When input exceeds 200%
flash '0000' |
| Power Supply |
AC 90 - 130 Volts AC 180
- 264 V
|
| Operation
temperature |
0~ 50 C, 35 - 85%
RH |
| Dimension mm H x W x
D |
48 x 96 x 89 mm 1/8 DIN
size |
| Weight |
Approx 250 gm (AC) |
| Dielectric
Strength |
AC Type input (lo)
terminal to ground DC500 V. Power supply teminal to input terminal, gound,
common and case AC 1500 Volts for 1 min. DC Type Input (lo) and power
supply, DC +/- 500V |
| Insulation
Resistance |
DC 500V 100 MOhm at above
terminals |
| BCD Output |
Parallel BCD open collector
output sink current 10 mA (MAX) Vce 30 V (MAX)
- Data ouput isolated
paralles BCD
- Overrange
when input
exceeds 9999, current sink
- Print Command
Current
sink for 1 mS after measurement is finished
|
| Analog Output |
- Voltage 0 - 1
V
- Accuracy 0.5% FS (23C to
+/-5C)
- Resolution 0.1
mV/digit
- External Resistance 20
KOhm or more
|
|
The online store of Topac Instrumentation
|
|
|
|