Multi point refrigerant safety monitor 301EM
|
|
|
|
Top > Air Quality > Wall Mount Safety Monitors > Multi point refrigerant safety monitor 301EM |
|
|
|
|
 |
Multi point refrigerant safety monitor 301EM SKU: VA301EM
Prices from: $1,250.00
|
|
Multi point refrigerant safety monitor 301EM Description
|
Easily configured to meet ASHRAE 15, B-52 and International Mechanical Code requirements, the 301EM is commonly used to optimize gas detection in mechanical and chiller rooms. A full complement of sensors (including toxic, oxygen, combustible gases and a full line of refrigerant sensors), horns, strobes and remote panels provide added flexibility to suit a variety of gas detection system solutions. monitors for R11, R12, R22, R123, R125, R134a – R410A
ASHRAE No 15-2001 Mechanical Standard and
B-52 Code Compliance
The ASHRAE and B-52 security standards have been established to minimize risk and protect the safety of mechanical room personnel and the environment at large. Available in a special configuration, the 301EM mechanical room controller has been carefully designed to meet and even exceed these rigorous standards. The Vulcain 301EM can be configured to offer automatic
fan, horn and strobe activation in addition to manual fan activation. Latching relay for manual alarm recognition, silence key for manual horn deactivation, built-in 24 Vdc outputs for horn operation, and 2 breakglass switch accessories for manual alarm activation ensure optimal performance.
| Power Requirement |
22-27 Vac, 29-38 Vdc, 2A max @ 29Vdc |
| Size |
28 x 20.3 x 7 cm (11.02 x 7.99 x 2.73 in.) |
| Weight |
1.02 kg (2.25 lb.) |
| Distance Between 301IRFS refrigerant sensors: |
Up to 200 ft. / 60.9 m |
| Controller and Sensor S301D2 toxic/combustible sensors: |
Up to 500 ft. / 152.4 m |
| Visual Indicators |
Normal Operation
Alarm Level 1
Alarm Level 2
Alarm Level 3
Signal Tx
Failure Indication |
Green LED
Red LED
Red LED
Red LED
Blinking amber LED
Yellow LED
|
| Alarm Levels |
3 with high and low setpoints |
|
| Outputs |
4 DPDT relays (alarms and/or fault), buzzer
Three 24 Vdc, 250 mA (per output)
Four 4-20 mA outputs
Modbus
RFS option: 24 Vdc built-in red strobe
RFSA option: 24 Vdc built-in red strobe & 105 dBA horn |
| Relay Output Rating |
5 A, 30 Vdc or 250 Vac (resistive load) |
| Ratings and Certifications |
Certified to CAN/CSA C22.2 No. 61010-1
116662
Conforms to ANSI/UL 61010-1 |
|
Gases Detected Gases Detected
Accuracy is +_ 3%
|
Detection Range |
Operating Temperature |
Operating Humidity Range |
| 301IRFS for Refrigerants |
| Trichlor°Fluoromethane (R11) |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| Dichlorodifluoromethane (R12) |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| Chlorodifluoromethane (R22) |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| Dichlorotrifluoroethane (R123) |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| Dichlorodifluoromethane(R125) |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| Tetrafluoroethane (R134a) |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| Heptafluoropropane(FE-227) |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| (HFC-227ea) |
|
|
|
| R410a |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| R404a |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| R507a (AZ50) |
0-1000 ppm |
0 to 40 °C (32 to 104°F) |
0-95% non-condensing |
| |
|
The online store of Topac Instrumentation
|
|
|
|